Loa Cinema Meyer Sound X-800c Giá Call

 Tình trạng: Chờ order
 Mã sản phẩm: X-800c
 Đã xem: 1.754.757.639
 Giá: 0₫

 

 

Acoustical

 

Operating Frequency Range1  20 Hz 200 Hz

Frequency Response2  23 Hz 160 Hz ±4 dB

Phase Response 32 Hz 175 Hz ±30° Maximum Peak SPL3  130 dB

Dynamic Range >110 dB

Coverage

 

Varies with number of units and configuration

Transducer

Low Frequency One 18” long-excursion cone driver

Nominal impedance: 4 Ω

Audio Input

Type Differential, electronically balanced

Maximum Common Mode Range ±15 V DC, clamped to earth for voltage transient protection

Connectors XLR 3-pin female input with XLR 3-pin male loop output

Input Impedance 10 differential between pins 2 and 3

Wiring Pin 1: Chassis/earth through 220 kΩ, 1000 pF, 15 V clamped network

to provide virtual ground lift at audio frequencies Pin 2: Signal +

Pin 3: Signal

Case: Earth ground and chassis

DC Blocking Differential DC blocking up to the maximum common mode voltage

CMRR >50 dB, typically 80 dB (50 Hz 500 Hz)

RF Filter Common mode: 425 kHz; Differential mode: 142 kHz

TIM Filter Integral to signal processing (<80 kHz)

Nominal Input Sensitivity 0 dBV (1.0 V rms, 1.4 V peak) continuous is typically the onset of

limiting for noise and music

Input Level Audio source must be capable of producing +20 dBV (10 V rms,

14 V peak) into 600 Ω to produce the maximum peak SPL over the

operating bandwidth of the loudspeaker

Amplifier

Type Single channel

Output Power4  450 W

Total Output 900 W peak THD, IM, TIM  <.02%

Load 4 Ω

Cooling Convection

AC Power

Connector powerCON 20 with loop output

Voltage Selection Automatic, continuous range from 90–265 V AC

Safety Agency Rated Operating Range 100–240 V AC, 50/60 Hz

Turn-on and Turn-off Points 90 V AC on, no turn-off, only fuse-protect above 265 V AC

Current Draw: Idle Current 0.26 A rms (115 V AC); 0.16 A rms (230 V AC); 0.30 A rms (100 V AC)

Maximum Long-Term Continuous Current (>10 sec) 1.4 A rms (115 V AC); 0.7 A rms (230 V AC); 1.6 A rms (100 V AC)

Burst Current (<1 sec)5  2.7 A rms (115 V AC); 1.1 A rms (230 V AC); 3.0 A rms (100 V AC)

Maximum Instantaneous Peak Current 9 A peak (115 V AC); 6 A peak (230 V AC); 10 A peak (100 V AC)

Inrush Current 10 A peak (115 V AC); 8 A peak (230 V AC); 10 A peak (100 V AC)

RMS Network (optional)

Equipped with two-conductor twisted-pair netw ork, reporting amplifier operating parameters to host computer